What size air conditioner do you need?
This air conditioner BTU calculator estimates how much cooling a room needs, in BTU per hour, watts and kilowatts. It then suggests the nearest standard unit size (7,000, 9,000, 12,000, 18,000 or 24,000 BTU/h), estimates the electricity the unit would use and includes a W, BTU/h and frigories converter. It works in square feet and feet by default; switch "Units" to metres if you prefer. The figures are common rules of thumb: a load calculation by an HVAC professional is what counts.
How to use it
- Under "I know", pick "the floor area and height" or "the volume", then enter your numbers.
- Set "Sun exposure", "Insulation" and "Climate". The climate options are described in °F.
- Enter the "Number of people" and the "Computers or screens switched on". Tick "Kitchen in the room" or "Under the roof or top floor" if they apply.
- Read the "Estimated cooling capacity", the suggested size and "How it was calculated".
- Under "Estimated electricity use", adjust the "Efficiency ratio (EER, W/W)" and the "Price per kWh" from your bill.
How the calculation works
The tool uses the volume method common in European sizing guides, which quote 30 to 40 W per cubic metre depending on conditions. It starts at 40 W/m³ (about 3.9 BTU/h per cubic foot) for a reference room with normal sun, average insulation and a mild climate. Adjustments are added together: hot climate +10% or very hot +20%, full sun +15% or shaded −10%, poor insulation +15% or good −10%, under the roof +15%. Then come 100 W (341 BTU/h) per person, 150 W per computer or screen and 1,000 W (3,412 BTU/h) for a kitchen. Since 1 W = 3.412 BTU/h, the total is converted at the end.
Bedroom of 130 ft² with an 8 ft ceiling, two people, reference conditions: 1,040 ft³, or 29.45 m³; 29.45 × 40 = 1,178 W, plus 200 W for the occupants, gives 4,702 BTU/h (1,378 W). The smallest common size, 7,000 BTU/h, covers it.
Living room of 320 ft² in full sun, 8 ft ceiling, three people: 2,560 ft³ (72.49 m³) × 46 W/m³ = 3,335 W, plus 300 W, gives 12,401 BTU/h (3,635 W). The tool suggests an 18,000 BTU/h unit and notes that a 12,000 BTU/h one would cover 96% of the load, so it would struggle on the hottest afternoons.
Many US sizing charts use about 20 BTU/h per square foot. This tool's reference works out at about 31 BTU/h per square foot for an 8 ft ceiling, so it lands on the generous side, which suits sunny rooms and window or portable units.
Running cost
Electrical power is the cooling output divided by the EER. For the living room: 3,635 ÷ 3 = 1,212 W. Running 8 hours a day, that is 9.69 kWh, or 1.94 at 0.20 per kWh; over 60 days, 582 kWh and 116.31. This is a ceiling, as a unit that has reached the set temperature slows down.
Converting BTU, watts and frigories
A 12,000 BTU/h unit (often called "one ton") delivers 3,517 W of cooling. The frigorie, used in Spain and Latin America, equals 1.163 W, so 3,000 frigories/h are 3,489 W.
Frequently asked questions
How many BTUs do I need for a 200 ft² room?
With an 8 ft ceiling, two people and reference conditions, the tool gives 6,866 BTU/h (2,012 W), so a 7,000 BTU/h unit.
Is a bigger air conditioner better?
No. An oversized unit cools quickly, then switches off before it has removed the humidity, leaving the room clammy. Pick the size just above the load.
What is EER?
The energy efficiency ratio here is cooling watts per electrical watt at full load. An EER of 3 means 3 W of cooling for every watt of electricity. US labels usually state EER in BTU/h per watt, often around 10 to 12: divide that figure by 3.412 before entering it, so 10.2 becomes about 3.
Can I rely on this for a central system?
No. It gives a ballpark figure for one room. A central or multi-zone system needs a full load calculation by a professional.